What failed in 2018, and why
Across the island, damage tracked distance from the rupturing fault. Street by street, it tracked how buildings were built. Here is the sequence, the mechanism, and what it means for anything you are shown today.
Checked 1 September 2026. Claims re-checked and corrected on 18 November 2026. Sources are listed at the end. Jump to them.
In the summer of 2018 Lombok was struck not by one earthquake but by a sequence, over three weeks, and the pattern of what fell down is the single most useful piece of information available to anyone buying a building on this island. It was not random. Across the island, damage tracked distance from the rupturing fault to the north. Street by street within the shaken zone, it tracked how the buildings had been built, and that second pattern is the one a buyer can act on.
That is an uncomfortable thing for a property page to say and a genuinely useful one, because construction method is checkable before you buy in a way that seismic risk is not.
The sequence
Five significant events, not one.
| Date, 2018 | Magnitude |
|---|---|
| 29 July | M 6.4 |
| 5 August | M 6.9 |
| 9 August | M 5.9 |
| 19 August | M 6.3 |
| 19 August | M 6.9 |
Magnitudes are USGS moment magnitudes; Indonesia's BMKG lists slightly different values for some events, including 7.0 for 5 August.
The sequence matters as much as any single magnitude. A building that survives a first shock with cracked but standing walls has lost strength it does not get back, and the next event finds it weaker. The 9 August aftershock collapsed buildings that the earlier shocks had already weakened. Any assessment of how a structure performed has to be read against the whole three weeks rather than one date.
The casualty and damage figures differ between sources, and we are not going to pick one silently. NOAA's National Centers for Environmental Information records, for the 5 August 2018 earthquake, 560 deaths, 7,733 injuries and 83,392 houses damaged, and gives no displaced figure. Indonesia's national disaster management agency, BNPB, put the toll at 563 to 564 deaths depending on the tally, with reported injuries between about 1,500 and 1,800, more than 417,000 displaced and 186,010 houses reported damaged at one cutoff; reconstruction records later counted 216,519 affected houses. The death tolls differ by no more than four, and the injury gap reflects interim tallies made during the sequence that counted light injuries. The gap in the house counts has a documented explanation: Indonesian reconstruction records distinguish about 75,000 houses heavily damaged or collapsed from a total of well over 200,000 affected to some degree. The smaller figure is the collapsed-and-condemned count, the larger the full damage register. NOAA's 83,392 falls between the two and states no cutoff date. Where you see a single confident number quoted without attribution, that is the thing to be suspicious of.
What both sets agree on is scale. Officials reported that at least 80 percent of structures in North Lombok were damaged or destroyed. Whatever the precise count, this was not a marginal event for the building stock.
The mechanism, in terms you can use
Most housing across Lombok, and across much of Indonesia, is masonry: brick or block walls. What separates a building that cracks from a building that collapses is what is holding those walls together when the ground moves sideways.
Unreinforced masonry, which is what mostly failed
Walls built of brick or block with mortar and nothing else. They are strong in compression, which is why they hold up a roof perfectly well for decades, and weak in tension and in bending, which is what an earthquake applies. When the ground moves horizontally a wall is pushed out of its own plane. Having nothing to hold it together across that direction, it cracks, then separates, then falls. Once a wall goes the roof it was carrying comes down with it, and the roof is what kills people.
A common local variant makes it worse rather than better: a house that looks like a reinforced concrete frame but is not one. Slender columns cast around the masonry with too little steel, ties or stirrups spaced too widely or absent at the joints, smooth rather than deformed bar, weak concrete, and no positive connection between the roof structure and the walls. It has the appearance of an engineered building and the behaviour of an unreinforced one.
Confined masonry, the type that holds together
The same masonry walls, built first, then confined by reinforced concrete tie-columns at the ends and corners and tie-beams above, cast against the completed wall panels so that concrete and masonry are bonded rather than merely adjacent. The frame does not carry the load in the way a moment frame does. It holds the wall panel together and stops it from disintegrating out of plane.
The result is a building that cracks, deforms, and stays standing long enough for people to get out. That is the whole objective. Earthquake-resistant does not mean undamaged, and any seller who implies it does is describing something that does not exist at residential budgets.
Structural engineers point to the same four details. Tie-columns and tie-beams present at every wall panel, corner and opening. Reinforcement continuous and properly lapped, with closely spaced ties at the joints where columns meet beams. Concrete cast against the masonry rather than the masonry stuffed into a completed frame. And a roof positively tied to the walls, so the structure behaves as one object. Absent any of these, the other three do less than you would hope.
What this means for something you are shown today
Two situations, and they call for different questions.
An existing building. Ask when it was built, and specifically whether it stood through 2018. A building that came through the sequence has demonstrated something, but it has also absorbed damage that may have been cosmetically repaired since. Fresh render on a building of the right age is a reason to look harder, not a reassurance. What you want is an independent structural engineer, appointed and paid by you, who will look at the load path, the joints and the roof connection rather than the finishes.
Anything being built now. The relevant standard is SNI 1726:2019, the Indonesian standard for earthquake-resistant design of building structures. One honest caveat: hazard studies published after 2018 indicate that the current code maps understate Lombok's hazard, so certification against the standard is a minimum to insist on, not a guarantee of performance. Ask for the soil investigation and for a structural design certified against that standard by a named engineer. "Built to international standards" names no standard and no engineer, and is therefore not an answer. The documents that evidence this are set out in the earthquake risk guide and appear on the document checklist under the off-plan and completed-building sets.
The honest summary is that Lombok is seismically active, that this is not a reason to avoid the island, and that it is a very good reason to care about who engineered the specific building you are buying. The 2018 sequence did not make that argument for us. It just made it impossible to ignore.
Common questions
How big were the 2018 Lombok earthquakes?
It was a sequence rather than a single event: M 6.4 on 29 July, M 6.9 on 5 August, M 5.9 on 9 August, and both M 6.3 and M 6.9 on 19 August 2018 (USGS moment magnitudes; Indonesia's BMKG lists slightly different values for some events, including 7.0 for 5 August). The sequence matters because a building damaged in an early shock enters the next one weaker, and the 9 August aftershock collapsed buildings that the earlier shocks had already weakened. Any account of how a building performed should cover the whole three weeks.
How many people died in the 2018 Lombok earthquake?
Sources differ and the difference is worth knowing. NOAA's National Centers for Environmental Information records, for the 5 August 2018 earthquake, 560 deaths, 7,733 injuries and 83,392 houses damaged, and gives no displaced figure. Indonesia's national disaster management agency, BNPB, put the toll at 563 to 564 deaths depending on the tally, with reported injuries between about 1,500 and 1,800, more than 417,000 displaced and 186,010 houses reported damaged at one cutoff; reconstruction records later counted 216,519 affected houses. The death tolls differ by no more than four. The injury gap reflects interim tallies made during the sequence that counted light injuries. The house counts have a documented explanation: reconstruction records distinguish about 75,000 houses heavily damaged or collapsed from a total of well over 200,000 affected to some degree. NOAA's 83,392 falls between the two and states no cutoff date.
What is confined masonry and why did it perform better?
Confined masonry is brick or block walls built first and then confined by reinforced concrete tie-columns and tie-beams cast against the completed panels, so that concrete and masonry bond together. Unreinforced masonry has no such confinement: it is strong under vertical load but weak when pushed sideways, so walls crack, separate and fall out of plane, bringing the roof down. Confinement holds the panel together, allowing the building to crack and deform while staying standing, which is the actual objective.
Does a building surviving 2018 mean it is safe?
It is evidence, not proof, and it cuts both ways. A building that stood through five significant events has demonstrated something real. It has also absorbed damage that may since have been repaired cosmetically, and masonry that has cracked does not recover its original strength. For any building of that age the sensible step is an assessment by a structural engineer you appoint and pay yourself, looking at the load path, the reinforcement at joints and the connection between roof and walls rather than at the finishes.
Sources
- 2018 Lombok earthquake sequence, USGS event pages: M 6.4 on 29 July, M 6.9 on 5 August, M 5.9 on 9 August, M 6.3 and M 6.9 on 19 August 2018 (moment magnitudes; Indonesia's BMKG lists slightly different values for some events, including 7.0 for 5 August). Checked 1 September 2026.
- NOAA National Centers for Environmental Information, significant earthquake database, record 10351 (Lombok, 5 August 2018): 560 deaths, 7,733 injuries, 83,392 houses damaged, damage USD 509 million; no displaced figure. ngdc.noaa.gov. Read through the NCEI hazard service on 18 November 2026.
- Indonesian National Board for Disaster Management (BNPB) figures as reported in academic review and reconstruction literature: 563 to 564 deaths depending on the tally, about 1,500 to 1,800 injured, more than 417,000 displaced, 186,010 houses reported damaged at one cutoff and 216,519 affected houses in reconstruction records, of which about 75,000 heavily damaged or collapsed; at least 80 percent of structures in North Lombok damaged or destroyed. BNPB's own releases were not re-read. Checked 1 September 2026.
- SNI 1726:2019, Indonesian standard for earthquake-resistant design of building structures. Named as the applicable standard; a possible later edition has not been confirmed.
- Confined masonry and unreinforced masonry behaviour under seismic loading is described here from established structural engineering practice rather than from a Lombok-specific damage survey. We have not read a post-2018 reconnaissance report in full, and no numerical breakdown of damage by construction type is claimed on this page.
General information, not engineering or legal advice. Nothing here is a substitute for an assessment of a specific building by a qualified structural engineer you appoint yourself. The mechanism described is general to masonry construction in seismic zones; how it applies to any particular property depends on that property.
Read next
Looking at an older building?
Tell us what you are looking for, and we write to you when a seller matches. If you would like our numbers on a property you have been shown, tick the Forecast box in the same form.